{{ message }}
Add cortex_ingester_active_native_histogram_series metric to track ac…#6695
Merged
yeya24 merged 1 commit intoApr 17, 2025
Conversation
yeya24
reviewed
Apr 15, 2025
yeya24
left a comment
Contributor
There was a problem hiding this comment.
This seems a very nice improvement. @harry671003 Can you help take a look?
harry671003
approved these changes
Apr 15, 2025
harry671003
left a comment
Contributor
There was a problem hiding this comment.
LGTM!
Should we also track native histogram samples separately in distributor?
yeya24
approved these changes
Apr 15, 2025
…tive # of NH series Signed-off-by: SungJin1212 <tjdwls1201@gmail.com>
7aca81c to
4b42a00
Compare
Member
Author
Contributor
friedrichg
approved these changes
Apr 16, 2025
3 tasks
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.

Currently, the metric
cortex_ingester_active_seriestracks the number of active series, including native histogram(NH) and float series. So, we cannot track the number of NH series only.This PR adds a
cortex_ingester_active_native_histogram_seriesmetric to track only the number of active NH series.Which issue(s) this PR fixes:
Fixes #
Checklist
CHANGELOG.mdupdated - the order of entries should be[CHANGE],[FEATURE],[ENHANCEMENT],[BUGFIX]